A-A-58004F
itemized technical proposal that describes how the proposed model complies with each salient
characteristic of this CID; a paragraph by paragraph response to the salient characteristics
section of this CID shall be provided. The response to each paragraph shall clearly state "Fully
Comply" or "Bid with Exception" in addition to other data the contractor wishes to submit. The
proposal shall be provided with the pricing submission. Failure to provide this information may
deem a vendor as non-responsive and their proposal may be rejected. The manufacturer shall
provide two copies of their commercial descriptive catalogs with their offer as supporting
reference to the itemized technical proposal. The manufacturer shall identify all modifications
made to their commercial model in order to comply with the requirements herein.
4.6 Inspection requirements.
4.6.1 General inspection requirements. Apparatus used in conjunction with the inspections
specified herein shall be laboratory precision type, calibrated at proper intervals to ensure
laboratory accuracy.
4.6.2 Test rejection criteria. Throughout all tests specified herein, the vehicle shall be closely
observed for the following conditions, which shall be cause for rejection:
a. Failure to conform to design or performance requirements specified herein or in the
contractor's technical proposal.
b. Any spillage or leakage of any liquid, including fuel, coolant, lubricant, or hydraulic
fluid, under any condition, except as allowed herein.
c. Structural failure of any component, including permanent deformation, or evidence of
impending failure.
d. Evidence of excessive wear.
e. Interference between the vehicle components or between the vehicle, the ground, and
all required obstacles, with the exception of normal contact by the tires.
f. Misalignment of components.
g. Evidence of undesirable roadability characteristics, including instability in handling
during cornering, braking, and while traversing all required terrain.
h. Conditions that present a safety hazard to personnel during operation, servicing, or
maintenance.
i. Overheating of the engine, transmission, or any other vehicle component.
j. Evidence of corrosion.
k. Failure of the firefighting system.