A-A-58004F
and controls shall be within reach of the driver and right front crew member. Siren activating
foot switches shall be located in front of the driver and the right front crew member. The siren
speaker shall be rated at 100 watts minimum and shall be located in a guarded position as low
and as far forward on the vehicle as practical.
2.4.5.2 Horn. Dual forward facing air horns shall be installed in protected locations near the front
of the truck. Air horn activating foot switches shall be located in front of the driver and the right
front crew member.
2.4.6 Work lighting.
2.4.6.1 Cab interior lights. Cab interior light levels shall be a minimum of 2 foot-candles.
2.4.6.2 Compartment lights. White lighting sufficient to provide an average minimum
illumination of 2 foot-candle shall be provided in each compartment greater than 4 cubic feet and
having an opening greater than 144 square inches. Where a shelf is provided, this illumination
shall be provided both above and below the shelf. Lights shall automatically illuminate only
when the respective door is opened and the vehicle electrical master switch is in the "on"
position. Light switches shall be of the magnetic (non-mechanical) type.
2.4.6.3 Ladder, step, walkway, and area lights. Non-glare white or amber lighting shall be
provided at ladders and access steps where personnel work or climb during night operations.
These area lights shall be controlled with switches on the cab instrument panel and near the light
sources.
2.4.6.4 Spotlights. Two halogen spotlights rated at 160,000 candlepower (CP) minimum each
shall be mounted on the cab roof and controlled from inside the cab.
2.4.7 Scene lights. A total of 8 12-volt LED high-mounted floodlights shall be provided to
illuminate the work areas around the tanker: two on each side, two at the rear, and two in the
front. Individual switches shall be located in the work areas and on the instrument panel. A
switch shall be provided to control the lights on the left side of the tanker, a second switch shall
be provided to control the lights on the right side of the tanker, and a third switch shall be
provided to control the lights at the rear of the tanker. A separate switch for the front lights shall
be located on the instrument panel only. Three way switches shall be used.
2.4.8 Radio circuit. The vehicle shall have two separate 30 amp circuits, with breakers and at
least 6-foot of wire routed to a space provided adjacent to the driver and turret operator for
purchaser provided radios and other electrical equipment. The wiring shall be tagged indicating
its purpose.
2.4.9 Radio Antennas. An antenna mounting base with coaxial cable and waterproof cap shall be
provided for 2 way radios. The mount shall be located on the cab roof to the rear of the front
passenger's seat and will be clear of any obstructions. The cable shall be routed from the roof to
the center console, length of the cable shall be determined at Post Award.
13
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business