A-A-58005C
e.
NATIONAL STOCK NUMBER (NSN)
f.
VEHICLE CURB WEIGHT: kg (pounds)
g.
PAYLOAD, MAXIMUM: kg (pounds)
h.
GROSS VEHICLE WEIGHT (GVW): kg (pounds)
i.
FUEL CAPACITY AND TYPE: gal (gallons) / L (liters)
j.
DATE OF DELIVERY (month and year)
k.
WARRANTY (months and km (miles))
l.
CONTRACT NUMBER
m.
PAINT COLOR AND NUMBER
n.
LENGTH, WIDTH, AND HEIGHT OF VEHICLE IN INCHES AND
CENTIMETERS.
2.2 General requirements.
2.2.1 Hose storage.
2.2.1.1 Hose storage area. The vehicle shall have a hose bed, with a removable and secured hose
bed cover and two adjustable dividers, capable of carrying 1,000 feet of 5-inch hose and 300 feet
of 3-inch hose. Hose bed covers will be red for red vehicles and tan for desert sand vehicles. The
hose storage area shall be equipped with a hose retention device to prevent inadvertent hose
deployment. Covers will be secured by snap fasteners.
2.2.1.2 Cross lay hose beds. The vehicle shall have three cross lay hose beds with one or more
removable covers. Two hose beds shall be capable of carrying 200 feet of 1¾-inch preconnected
hose each. The third hose bed shall be capable of carrying 200 feet of 3-inch hose. Sufficient
clearance shall be provided between the hose and cover to allow a preconnected hose nozzle to
be pulled through from either side of the vehicle. Cross lay hose bed covers shall be red in color
for vehicles painted Candy Apple Red. For vehicles painted Desert Sand, cross lay hose bed
covers shall be tan in color. Covers will be secured by snap fasteners.
2.2.1.3 Hose board trays. The vehicle shall be equipped with one drop in running board
hose/equipment tray located under the discharge panel on the fire officer s side. The tray shall
be equipped with a mat and shall be designed to allow for proper drainage.
2.2.2 Soft suction hose. The vehicle shall be equipped with a 20 foot long, 5-inch soft suction
hose in accordance with NFPA 1961, with a 4½-inch long handle National Hose thread female
coupler on one end and a 6-inch long handle National Hose thread female coupler on the
opposite end. The couplers shall be in accordance with NFPA 1963. The soft suction hose and
couplers shall be stored in a compartment between the truck cab and the extended front bumper.
2.2.3 Ground ladders. Ground ladders shall be provided as listed in 8.7 of NFPA 1901 and shall
be of aluminum construction. The ground ladders shall be mounted in locations readily
accessible to personnel standing on the ground. Each ladder shall be individually accessible; it
shall not be necessary to remove or relocate one ladder to access another ladder. The ground
ladder mounting system design shall be subject to approval by the procuring activity.
2.2.4 Minor equipment.
7