2.4.4 Warning lights. All warning lights shall use light emitting diode (LED) elements. The
warning light system, related components, and devices shall be in accordance with 13.8 of NFPA
1901.
2.4.4.1 Light bars. A six element LED light bar, or two three element LED light bars, with both
forward and side facing heads, shall be mounted on the cab roof. Forward facing lenses shall be
red-white-red-red-white-red, with the white lights switched off in blocking right-of-way mode.
Rearward facing lenses shall be red-amber-red-red-amber-red. The light bar shall be separately
switched from the warning light panel. All trucks shall be equipped with a steady red front
warning light as required by California state law regardless of shipping destination.
2.4.4.2 Warning light color. When specified (see 6.2), the rearward, red lights shall be replaced
with amber. When specified (see 6.2), all red warning and lights shall be replaced with blue.
2.4.4.3 Headlight flashing system. A high beam, alternating/flashing, headlight system shall be
provided. The headlight flasher shall be separately switched from the warning light panel.
2.4.5 Audible warning devices.
2.4.5.1 Siren. The vehicle shall be equipped with an electronic siren system. The amplifier unit
shall include volume control and selection of "Radio," "PA," "Manual," "Yelp," "Wail," and "Hi-
Lo" (European) modes, and a magnetic noise canceling microphone. The amplifier, microphone,
and controls shall be within reach of the driver and right front passenger. Siren activating foot
switches shall be located in front of the driver and the right front passenger. The siren speaker
shall be rated at 100 watts minimum and shall be located in a guarded position in the front
bumper.
2.4.5.2 Horn. Dual forward facing air horns shall be installed in protected locations near the front
of the truck. Air horn activating foot switches shall be located in front of the driver and the right
front passenger.
2.4.6 Work lighting.
2.4.6.1 Cab interior lights. Cab interior light levels shall be sufficient for reading maps or
manuals.
2.4.6.2 Compartment lights. White lighting sufficient to provide an average minimum
illumination of 2.0 foot-candle shall be provided in each compartment greater than 4.0 cubic feet
and having an opening greater than 144 square inches. Where a shelf is provided, this
illumination shall be provided both above and below the shelf. Lights shall automatically
illuminate only when the respective doors are opened.
2.4.6.3 Ladder, step, and area lights. Non-glare white lighting shall be provided at ladders and
access steps where personnel work or climb during night operations. These area lights shall be
controlled with switches on the cab instrument panel and near the light sources.